BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//AIA Winston-Salem - ECPv6.3.1//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:AIA Winston-Salem
X-ORIGINAL-URL:https://www.aiawinstonsalem.org
X-WR-CALDESC:Events for AIA Winston-Salem
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:America/New_York
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20210314T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20211107T060000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20210407T120000
DTEND;TZID=America/New_York:20210407T130000
DTSTAMP:20260423T235306
CREATED:20210407T202235Z
LAST-MODIFIED:20210407T202235Z
UID:1214-1617796800-1617800400@www.aiawinstonsalem.org
SUMMARY:PUSHING THE ENVELOPE
DESCRIPTION:CONTINUOUS INSULATION SOLUTIONS FOR THIN ADHERED MASONRY VENEERS – PTEICB\n*1 HSW*\n\n\n\n\nT-Clear was the first company to mass produce concrete board and was ahead of their time with the creation of Insulated Concrete Board Panels as far back as a decade ago. T-Clear’s foresight has allowed the ProGUARD DP® Insulated Concrete Board Panels to be adopted and used across North America over those years\, and they are revolutionizing the thin adhered masonry veneer world\, helping the industry\, architects\, designers\, GC’s and installers meet the ever-changing wall cladding construction landscape as a result of the Energy Codes. We will discuss and explore Engineered and Tested Continuous Insulation (CI) solutions for thin adhered masonry veneers to meet the requirements of the Energy Code anywhere in North America.\n\n\nSpecifically\, we will focus on: \n• Understanding Insulated Concrete Board Panels and their benefits and advantages and why we need insulated concrete board in todays world \n• How to achieve an Energy Code (ASHRAE 90.1/IECC/SB-10) compliant wall design when using an adhered masonry veneer installed over Insulated Concrete Board Panels to meet Continuous Insulation (CI) requirements \n• The mechanisms of adhered masonry veneer failures of the past and how insulated concrete boards and new polymer fortified mortar systems address and eliminate these concerns \n• General wall construction with insulated concrete board panels and thin adhered veneers \n• Fire Resistance and NFPA-285 compliance with insulated concrete board panels (when foam plastic insulations are being used)
URL:https://www.aiawinstonsalem.org/event/pushing-the-envelope/
LOCATION:NC
CATEGORIES:Webinar
ATTACH;FMTTYPE=image/png:https://www.aiawinstonsalem.org/wp-content/uploads/2020/12/arriscraft-logo.png
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20210413T120000
DTEND;TZID=America/New_York:20210413T133000
DTSTAMP:20260423T235306
CREATED:20210407T213022Z
LAST-MODIFIED:20210407T213022Z
UID:1225-1618315200-1618320600@www.aiawinstonsalem.org
SUMMARY:April O.W.L.S. Webinar
DESCRIPTION:Pathways to Resilience with CRMCA/NRMCA\n*1.5 HSW Hours*\nGiven the increased frequency of natural disasters\, the need to design and build with more resilient materials and methods has become paramount. When we do\, we affect the long-term sustainability of a structure\, its overall life cycle\, and its direct environmental impact. In this course\, we will analyze and discuss how building with resilient materials and methods will reduce our carbon footprint\, positively affect our environment\, and help alter the course of environmental climate change overall.
URL:https://www.aiawinstonsalem.org/event/april-o-w-l-s-webinar/
LOCATION:NC
CATEGORIES:AIA North Carolina,O.W.L.S.
ATTACH;FMTTYPE=image/png:https://www.aiawinstonsalem.org/wp-content/uploads/2021/04/crmca.png
ORGANIZER;CN="AIA North Carolina":MAILTO:info@aianc.org
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20210421T123000
DTEND;TZID=America/New_York:20210421T143000
DTSTAMP:20260423T235306
CREATED:20210407T204403Z
LAST-MODIFIED:20210407T204403Z
UID:1217-1619008200-1619015400@www.aiawinstonsalem.org
SUMMARY:THIN ADHERED MASONRY DETAILING FOR THE MODERN AGE
DESCRIPTION:PROPER THIN ADHERED MASONRY DETAILING FOR THE MODERN AGE AND ENERGY CODES\n*2 HSW*\nIn this presentation\, we discuss the design and construction factors that impact the long-term performance of continuously insulated thin adhered masonry veneers assemblies that meet the requirements of the Energy Code. Architectural detailing for thin adhered masonry veneers promoting moisture management principles and considerations for control of movement in thin adhered masonry walls are covered. \nSpecifically\, we will focus on:\n• Understand the detailing elements required for effective moisture management in the various key areas of masonry veneer walls.\n• Understand how to design and detail thin adhered masonry to the requirements of the Energy Codes\n• Identify guidelines to follow in the design of a movement joint system to control differential movement in thin adhered masonry veneer walls.\n• Appreciate the effects of workmanship and environmental factors in the effective implementation of the design.
URL:https://www.aiawinstonsalem.org/event/thin-adhered-masonry-detailing-for-the-modern-age/
LOCATION:NC
CATEGORIES:Webinar
ATTACH;FMTTYPE=image/png:https://www.aiawinstonsalem.org/wp-content/uploads/2020/12/arriscraft-logo.png
END:VEVENT
END:VCALENDAR